<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-16 16-49-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -9 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 71 kHz 10100 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,8 dBr 7,45 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 16:49, 16.06.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (58 dBuV) Max at: 71 kHz MIN: 13 kHz % above 75 kHz: 0,0000 Acquired: 2025/06/16 16:48:22 Total samples: 10100 Equivalent time: 0:08:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,0 dBr MIN: 6,8 dBr AVE: 7,45 dBr % above 10,2 dBr: 0,0 Last value: 7,9 dBr (2025/06/16 16:48:22) Station: 96.90 MHz, signal: 5/5 (58 dBuV) 16:41 16:42 16:43 16:44 16:45 16:46 16:47 16:48 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality